top of page

Genfloor / Epoxy Topcoats / 622 Genfloor Topcoat SB

Gen Boya 622 Genfloor Topcoat SB ambalaj görseli

EPOXY TOPCOATS · TOPCOAT

622

Genfloor Topcoat SB

2K · Solvent-borne epoxy · Gloss

Gloss, solvent-borne epoxy floor paint that prevents dusting.

A two-component, gloss floor topcoat made of solvent-borne epoxy resin and hardener. It prevents dusting on concrete and forms a durable, easy-to-clean surface.

Technical Data

LIANT

Epoxy resin

COMPOSANTS

Two-component (2K)

POSITION DANS LE SYSTÈME

Topcoat

DENSITÉ

1.55 ± 0.1 kg/L

EXTRAIT SEC EN VOLUME

55% ± 3

BRILLANT / ASPECT

Gloss

DILUTION

016 Gen Epoxy Thinner

MÉTHODE D’APPLICATION

Roller, brush, airless spray

PRÉPARATION DE SURFACE

Milling / shot-blasting, moisture < 4%

RENDEMENT

—

RENDEMENT

—

RENDEMENT

—

SÉCHAGE

—

CONDITIONNEMENT

—

TEINTE

Produced on request in colours from the RAL colour chart.

DOCUMENTS TECHNIQUES

Utilisation et application

DOMAINES D’UTILISATION

Used as a floor coating in areas without heavy traffic in industrial plants where concrete dusting affects production, and in petrochemical and other industrial facilities.

 

PRÉPARATION DE SURFACE ET APPLICATION

New concrete must be cured for at least 28 days; surface moisture must not exceed 4%. Remove weak surface layers, laitance, oil, curing compounds and old coating residues by milling, shot-blasting or diamond grinding; remove the dust with an industrial vacuum. Repair cracks and holes with epoxy repair mortar. Prime the surface with 643 Genfloor Primer Impregnation SB. Mix components A and B with a low-speed mechanical mixer until homogeneous (at least 2–3 minutes) and apply the mix within its pot life. Apply two coats by roller or brush. Ambient and floor temperature must be between +10 °C and +30 °C and relative humidity below 80%; floor temperature must be kept at least 3 °C above the dew point.

 

 

Technical data are average values at 20 °C and 65% relative humidity. Coverage varies with surface roughness, application method and film thickness. Consult the Gen Boya technical team for project-specific system design.

POINTS FORTS

— Prevents dusting

— Gloss, easy-to-clean surface

— Economical roller application

— Chemical resistance

SYSTÈME RECOMMANDÉ

PRIMAIRE

643 Genfloor Primer Impregnation SB

Le bon système pour votre sol, avec l’équipe technique Genfloor.

Nos experts vous accompagnent à chaque étape : analyse du support, mesure d’humidité, choix du système et calcul de consommation.

bottom of page