Genfloor / Primers and Impregnations / 642 Genfloor Moisture Barrier

PRIMERS AND IMPREGNATIONS · MOISTURE-BARRIER PRIMER
642
Genfloor Moisture Barrier
2K · Solvent-free epoxy · Moisture tolerant
Solvent-free, moisture-tolerant epoxy surface impregnating primer and moisture barrier.
A solvent-free, epoxy-based, moisture-tolerant surface impregnating primer. It offers good penetration, chemical resistance and high mechanical strength, allowing the coating system to be applied safely on damp concrete.
Technical Data
LIANT
Epoxy resin
COMPOSANTS
Two-component (2K)
POSITION DANS LE SYSTÈME
Moisture-barrier primer
DENSITÉ
1.08 ± 0.05 kg/L
EXTRAIT SEC EN VOLUME
Solvent-free (~100%)
RENDEMENT THÉORIQUE
200–250 g/m² (depending on substrate)
DILUTION
Do not thin
MÉTHODE D’APPLICATION
Roller, brush
PRÉPARATION DE SURFACE
Milling / shot-blasting; suitable for damp substrates
RENDEMENT
—
RENDEMENT
—
RENDEMENT
—
SÉCHAGE
Dust dry 3–4 h · Touch dry 8–10 h · Full cure 7 days
CONDITIONNEMENT
15 kg kit (10 kg A + 5 kg B)
TEINTE
—
DOCUMENTS TECHNIQUES
Utilisation et application
DOMAINES D’UTILISATION
Used on the interior surfaces of concrete water tanks, for fixing rebar starters in port and construction concrete, in car service stations and car parks, warehouses and bonded stores, factories and plants, aircraft and helicopter hangars, hospitals and laboratories.
PRÉPARATION DE SURFACE ET APPLICATION
New concrete must be cured for at least 28 days; there must be no standing water on the surface. Remove weak surface layers, laitance, oil, curing compounds and old coating residues by milling, shot-blasting or diamond grinding; remove the dust with an industrial vacuum. Repair cracks and holes with epoxy repair mortar. Mix components A and B with a low-speed mechanical mixer until homogeneous (at least 2–3 minutes) and apply the mix within its pot life. Apply by roller or brush; apply the next coat within 24 hours at the latest.
DOMAINES D’APPLICATION
→ Chemical, Petrochemical and Treatment
→ Aircraft Hangars and Defence Industry
Technical data are average values at 20 °C and 65% relative humidity. Coverage varies with surface roughness, application method and film thickness. Consult the Gen Boya technical team for project-specific system design.
POINTS FORTS
— Can be applied on damp concrete
— High penetration
— Chemical and mechanical resistance
— Barrier against moisture-induced blistering
SYSTÈME RECOMMANDÉ
COUCHES SUIVANTES
Can be completed with all Genfloor epoxy topcoat and self-levelling systems.