Solvent-free, high-strength conductive epoxy primer for antistatic and ESD floor systems.

A solvent-free, high-strength, epoxy-based conductive floor primer. Together with the antistatic topcoat it forms an earthed conductive floor system.

Technical Data

LIANT

Epoxy resin

COMPOSANTS

Two-component (2K)

POSITION DANS LE SYSTÈME

Conductive intermediate primer

DENSITÉ

1.10 ± 0.05 kg/L

EXTRAIT SEC EN VOLUME

Solvent-free (~100%)

DILUTION

Do not thin

MÉTHODE D’APPLICATION

Roller

PRÉPARATION DE SURFACE

Milling / shot-blasting, moisture < 4%

RENDEMENT

—

RENDEMENT

—

RENDEMENT

—

RENDEMENT

—

SÉCHAGE

—

CONDITIONNEMENT

—

TEINTE

Black

DOCUMENTS TECHNIQUES

Utilisation et application

DOMAINES D’UTILISATION

Applied in aircraft hangars, automotive plants, defence manufacturing facilities, healthcare laboratories, paint shops, electrical and electronics laboratories, and areas with sensitive electronic equipment and a high explosion risk.

 

PRÉPARATION DE SURFACE ET APPLICATION

New concrete must be cured for at least 28 days; surface moisture must not exceed 4%. Remove weak surface layers, laitance, oil, curing compounds and old coating residues by milling, shot-blasting or diamond grinding; remove the dust with an industrial vacuum. Repair cracks and holes with epoxy repair mortar. Prime the surface with 640 Genfloor Primer and lay copper strips for earthing. Mix components A and B with a low-speed mechanical mixer until homogeneous (at least 2–3 minutes) and apply the mix within its pot life. Apply by roller. Ambient and floor temperature must be between +10 °C and +30 °C and relative humidity below 80%; floor temperature must be kept at least 3 °C above the dew point.

 

DOMAINES D’APPLICATION

→ Electronics and ESD Areas

→ Aircraft Hangars and Defence Industry

 

Technical data are average values at 20 °C and 65% relative humidity. Coverage varies with surface roughness, application method and film thickness. Consult the Gen Boya technical team for project-specific system design.

POINTS FORTS

— Conductive interlayer

— Carrier primer of antistatic systems

— High strength

— Solvent-free

SYSTÈME RECOMMANDÉ

PRIMAIRE

640 Genfloor Primer

COUCHES SUIVANTES

664 Genfloor Antistatic Coating

Le bon système pour votre sol, avec l’équipe technique Genfloor.

Nos experts vous accompagnent à chaque étape : analyse du support, mesure d’humidité, choix du système et calcul de consommation.