Genfloor / Epoxy Topcoats / 655 Genfloor HB Flex Epoxy Coating

EPOXY TOPCOATS · FLEXIBLE TOPCOAT
655
Genfloor HB Flex Epoxy Coating
2K · Solvent-free epoxy · Flexible
Flexible, solvent-free modified epoxy topcoat for forklift and heavy vehicle traffic.
A two-component, solvent-free flexible topcoat made of modified epoxy resin and hardener. Its flexible structure provides resistance to cracking under impact and vibration.
Technical Data
LIANT
Modified epoxy
COMPOSANTS
Two-component (2K)
POSITION DANS LE SYSTÈME
Flexible topcoat
DENSITÉ
1.55 kg/L
EXTRAIT SEC EN VOLUME
Solvent-free (~100%)
DILUTION
Do not thin
MÉTHODE D’APPLICATION
Trowel, squeegee, spiked roller
PRÉPARATION DE SURFACE
Milling / shot-blasting, moisture < 4%
RENDEMENT
—
RENDEMENT
—
RENDEMENT
—
RENDEMENT
—
SÉCHAGE
—
CONDITIONNEMENT
—
TEINTE
Produced on request in colours from the RAL colour chart.
DOCUMENTS TECHNIQUES
Utilisation et application
DOMAINES D’UTILISATION
Applied in warehouses, factories and workshops with forklift, loader and heavy vehicle traffic, and in production and packaging areas.
PRÉPARATION DE SURFACE ET APPLICATION
New concrete must be cured for at least 28 days; surface moisture must not exceed 4%. Remove weak surface layers, laitance, oil, curing compounds and old coating residues by milling, shot-blasting or diamond grinding; remove the dust with an industrial vacuum. Repair cracks and holes with epoxy repair mortar. Prime the surface with 645 Genfloor Primer Flex. Mix components A and B with a low-speed mechanical mixer until homogeneous (at least 2–3 minutes) and apply the mix within its pot life. Apply by trowel and squeegee. Ambient and floor temperature must be between +10 °C and +30 °C and relative humidity below 80%; floor temperature must be kept at least 3 °C above the dew point.
DOMAINES D’APPLICATION
→ Factories and Production Plants
→ Warehouses and Logistics Centres
Technical data are average values at 20 °C and 65% relative humidity. Coverage varies with surface roughness, application method and film thickness. Consult the Gen Boya technical team for project-specific system design.
POINTS FORTS
— Flexible, impact-absorbing film
— Resistant to heavy vehicle traffic
— Solvent-free
— Resistance to cracking
SYSTÈME RECOMMANDÉ
PRIMAIRE
645 Genfloor Primer Flex or 640 Genfloor Primer