top of page

Genfloor / Self-Levelling Systems / 658 Genfloor HB Topcoat

Gen Boya 658 Genfloor HB Topcoat ambalaj görseli

SELF-LEVELLING SYSTEMS · SELF-LEVELLING TOPCOAT

658

Genfloor HB Topcoat

2K · Solvent-free epoxy · High strength

Solvent-free self-levelling epoxy coating with high mechanical strength and chemical resistance.

A solvent-free, self-levelling, epoxy-based coating with high mechanical strength and chemical resistance. Once fully cured it resists water, salt solutions, alkalis, dilute acids, petrol and mineral oils.

Technical Data

LIANT

Epoxy resin

COMPOSANTS

Two-component (2K)

POSITION DANS LE SYSTÈME

Self-levelling topcoat

DENSITÉ

1.75 ± 0.1 kg/L

EXTRAIT SEC EN VOLUME

Solvent-free (~100%)

DILUTION

Do not thin

MÉTHODE D’APPLICATION

Notched trowel, squeegee, spiked roller

PRÉPARATION DE SURFACE

Milling / shot-blasting, moisture < 4%

RENDEMENT

—

RENDEMENT

—

RENDEMENT

—

RENDEMENT

—

SÉCHAGE

—

CONDITIONNEMENT

—

TEINTE

Produced on request in colours from the RAL colour chart.

DOCUMENTS TECHNIQUES

Utilisation et application

DOMAINES D’UTILISATION

Used in car service stations and car parks, warehouses and bonded stores, textile workshops and factories, machinery manufacturing and assembly, electronics, automotive, food and paper plants, bottling and filling plants and laboratories.

 

PRÉPARATION DE SURFACE ET APPLICATION

New concrete must be cured for at least 28 days; surface moisture must not exceed 4%. Remove weak surface layers, laitance, oil, curing compounds and old coating residues by milling, shot-blasting or diamond grinding; remove the dust with an industrial vacuum. Repair cracks and holes with epoxy repair mortar. Prime the surface with 640 Genfloor Primer. Mix components A and B with a low-speed mechanical mixer until homogeneous (at least 2–3 minutes) and apply the mix within its pot life. Spread with a squeegee and notched trowel and de-aerate with a spiked roller. Ambient and floor temperature must be between +10 °C and +30 °C and relative humidity below 80%; floor temperature must be kept at least 3 °C above the dew point.

 

DOMAINES D’APPLICATION

→ Factories and Production Plants

→ Aircraft Hangars and Defence Industry

 

Technical data are average values at 20 °C and 65% relative humidity. Coverage varies with surface roughness, application method and film thickness. Consult the Gen Boya technical team for project-specific system design.

POINTS FORTS

— High mechanical strength

— Resistant to water, salt solutions, alkalis, dilute acids and oils

— Self-levelling structure

— Solvent-free

SYSTÈME RECOMMANDÉ

PRIMAIRE

640 Genfloor Primer

Le bon système pour votre sol, avec l’équipe technique Genfloor.

Nos experts vous accompagnent à chaque étape : analyse du support, mesure d’humidité, choix du système et calcul de consommation.

bottom of page