top of page

Genfloor / Epoxy Topcoats / 659 Genfloor Topcoat SF

Gen Boya 659 Genfloor Topcoat SF ambalaj görseli

EPOXY TOPCOATS · TOPCOAT

659

Genfloor Topcoat SF

2K · Solvent-free epoxy · Topcoat

Hygienic, smooth-finish, solvent-free epoxy floor paint for pedestrian and light vehicle traffic.

A two-component, hygienic, solvent-free epoxy topcoat with a smooth finish, applied on concrete and suitable for floors with pedestrian and light vehicle traffic.

Technical Data

LIANT

Epoxy resin

COMPOSANTS

Two-component (2K)

POSITION DANS LE SYSTÈME

Topcoat

DENSITÉ

1.45 ± 0.1 kg/L

EXTRAIT SEC EN VOLUME

Solvent-free (~100%)

BRILLANT / ASPECT

Gloss

RENDEMENT THÉORIQUE

3 m²/kg (single coat)

RAPPORT DE MÉLANGE

4 : 1 by weight (A : B)

DILUTION

Do not thin

MÉTHODE D’APPLICATION

Roller, trowel, squeegee

PRÉPARATION DE SURFACE

Milling / shot-blasting, moisture < 4%

RENDEMENT

—

SÉCHAGE

Dust dry 6–8 h · Touch dry 10–12 h · Full cure 7 days (23 °C)

CONDITIONNEMENT

20 kg kit (16 kg A + 4 kg B)

TEINTE

Produced on request in colours from the RAL colour chart.

DOCUMENTS TECHNIQUES

Utilisation et application

DOMAINES D’UTILISATION

Used in production and storage areas with forklift traffic, loading ramps, supermarkets, multi-storey and underground car parks, exhibition halls.

 

PRÉPARATION DE SURFACE ET APPLICATION

New concrete must be cured for at least 28 days; surface moisture must not exceed 4%. Remove weak surface layers, laitance, oil, curing compounds and old coating residues by milling, shot-blasting or diamond grinding; remove the dust with an industrial vacuum. Repair cracks and holes with epoxy repair mortar. Prime the surface with 640 Genfloor Primer; apply the topcoat within 24 hours of priming. Mix components A and B with a low-speed mechanical mixer until homogeneous (at least 2–3 minutes) and apply the mix within its pot life. Apply by roller, trowel or squeegee. Ambient and floor temperature must be between +10 °C and +30 °C and relative humidity below 80%; floor temperature must be kept at least 3 °C above the dew point.

 

DOMAINES D’APPLICATION

→ Factories and Production Plants

→ Car Parks and Ramps

 

Technical data are average values at 20 °C and 65% relative humidity. Coverage varies with surface roughness, application method and film thickness. Consult the Gen Boya technical team for project-specific system design.

POINTS FORTS

— Smooth, hygienic finish

— Solvent-free, low odour

— Easy to clean

— RAL colour options

SYSTÈME RECOMMANDÉ

PRIMAIRE

640 Genfloor Primer

Le bon système pour votre sol, avec l’équipe technique Genfloor.

Nos experts vous accompagnent à chaque étape : analyse du support, mesure d’humidité, choix du système et calcul de consommation.