top of page

Genfloor / Self-Levelling Systems / 660 Genfloor Self Levelling Topcoat

Gen Boya 660 Genfloor Self Levelling Topcoat ambalaj görseli

SELF-LEVELLING SYSTEMS · SELF-LEVELLING TOPCOAT

660

Genfloor Self Levelling Topcoat

2K · Solvent-free epoxy · Self-levelling

Gloss, solvent-free self-levelling epoxy floor coating resistant to forklift traffic.

A two-component, solvent-free, self-levelling epoxy topcoat. It forms a seamless, glossy, easy-to-clean surface with high mechanical strength and chemical resistance.

Technical Data

LIANT

Epoxy resin

COMPOSANTS

Two-component (2K)

POSITION DANS LE SYSTÈME

Self-levelling topcoat

DENSITÉ

1.65 ± 0.1 kg/L

EXTRAIT SEC EN VOLUME

Solvent-free (~100%)

BRILLANT / ASPECT

Gloss

RENDEMENT THÉORIQUE

1.5 kg/m² per 1 mm thickness

RAPPORT DE MÉLANGE

4 : 1 by weight (A : B)

DILUTION

Do not thin

MÉTHODE D’APPLICATION

Notched trowel, squeegee, spiked roller

PRÉPARATION DE SURFACE

Milling / shot-blasting, moisture < 4%

RENDEMENT

—

SÉCHAGE

Dust dry 3–4 h · Touch dry 10–12 h · Full cure 7 days

CONDITIONNEMENT

20 kg kit (16 kg A + 4 kg B)

TEINTE

Produced on request in colours from the RAL colour chart.

DOCUMENTS TECHNIQUES

Utilisation et application

DOMAINES D’UTILISATION

Used in production and storage areas with forklift traffic, loading ramps, supermarkets, multi-storey and underground car parks, exhibition halls and all areas requiring mechanical resistance.

 

PRÉPARATION DE SURFACE ET APPLICATION

New concrete must be cured for at least 28 days; surface moisture must not exceed 4%. Remove weak surface layers, laitance, oil, curing compounds and old coating residues by milling, shot-blasting or diamond grinding; remove the dust with an industrial vacuum. Repair cracks and holes with epoxy repair mortar. Prime the surface with 640 Genfloor Primer. Mix components A and B with a low-speed mechanical mixer until homogeneous (at least 2–3 minutes) and apply the mix within its pot life. Pour the mix onto the floor, spread with a notched trowel or squeegee and de-aerate with a spiked roller. Ambient and floor temperature must be between +10 °C and +30 °C and relative humidity below 80%; floor temperature must be kept at least 3 °C above the dew point.

 

DOMAINES D’APPLICATION

→ Factories and Production Plants

→ Warehouses and Logistics Centres

→ Pharmaceutical, Hospital and Laboratory

→ Shopping Centres, Retail, Schools and Offices

 

Technical data are average values at 20 °C and 65% relative humidity. Coverage varies with surface roughness, application method and film thickness. Consult the Gen Boya technical team for project-specific system design.

POINTS FORTS

— Seamless, smooth and glossy surface

— Resistant to forklift and heavy traffic

— Chemical resistance

— Hygienic and easy to clean

— RAL colour options

SYSTÈME RECOMMANDÉ

PRIMAIRE

640 Genfloor Primer (with 657 Self Levelling Basecoat as intermediate coat if required)

Le bon système pour votre sol, avec l’équipe technique Genfloor.

Nos experts vous accompagnent à chaque étape : analyse du support, mesure d’humidité, choix du système et calcul de consommation.

bottom of page