top of page

Genfloor / Self-Levelling Systems / 661 Genfloor Nova Self Levelling Topcoat

Gen Boya 661 Genfloor Nova Self Levelling Topcoat ambalaj görseli

SELF-LEVELLING SYSTEMS · CHEMICAL-RESISTANT TOPCOAT

661

Genfloor Nova Self Levelling Topcoat

2K · Novolac epoxy · Topcoat

Novolac epoxy self-levelling topcoat resistant to petroleum products, alkalis and weak acids.

A two-component, high-solids floor topcoat based on novolac (phenolic) epoxy with a modified phenolic polyamine hardener, offering excellent adhesion.

Technical Data

LIANT

Novolac (phenolic) epoxy

COMPOSANTS

Two-component (2K)

POSITION DANS LE SYSTÈME

Chemical-resistant topcoat

DENSITÉ

1.55 ± 0.1 kg/L

EXTRAIT SEC EN VOLUME

Solvent-free (~100%)

DILUTION

Do not thin

MÉTHODE D’APPLICATION

Notched trowel, squeegee, spiked roller

PRÉPARATION DE SURFACE

Milling / shot-blasting, moisture < 4%

RENDEMENT

—

RENDEMENT

—

RENDEMENT

—

RENDEMENT

—

SÉCHAGE

—

CONDITIONNEMENT

—

TEINTE

Produced on request in colours from the RAL colour chart.

DOCUMENTS TECHNIQUES

Utilisation et application

DOMAINES D’UTILISATION

Ideal where excellent chemical resistance to salt and fresh water, petroleum products, crude oil, alkalis and weak acids is required, particularly in heavy industrial atmospheres.

 

PRÉPARATION DE SURFACE ET APPLICATION

New concrete must be cured for at least 28 days; surface moisture must not exceed 4%. Remove weak surface layers, laitance, oil, curing compounds and old coating residues by milling, shot-blasting or diamond grinding; remove the dust with an industrial vacuum. Repair cracks and holes with epoxy repair mortar. The system is applied over 646 Novolac primer and 656 Nova Basecoat. Mix components A and B with a low-speed mechanical mixer until homogeneous (at least 2–3 minutes) and apply the mix within its pot life. Spread with a squeegee and notched trowel and de-aerate with a spiked roller. Ambient and floor temperature must be between +10 °C and +30 °C and relative humidity below 80%; floor temperature must be kept at least 3 °C above the dew point.

 

DOMAINES D’APPLICATION

→ Chemical, Petrochemical and Treatment

 

Technical data are average values at 20 °C and 65% relative humidity. Coverage varies with surface roughness, application method and film thickness. Consult the Gen Boya technical team for project-specific system design.

POINTS FORTS

— Heavy-duty chemical resistance

— Resistance to petroleum and crude oil

— Seamless, self-levelling surface

— Suitable for heavy industrial atmospheres

SYSTÈME RECOMMANDÉ

PRIMAIRE

646 Genfloor Novolac Epoxy Concrete Primer + 656 Nova SL Basecoat

Le bon système pour votre sol, avec l’équipe technique Genfloor.

Nos experts vous accompagnent à chaque étape : analyse du support, mesure d’humidité, choix du système et calcul de consommation.

bottom of page