top of page

Genfloor / Special Performance Systems / 664 Genfloor Antistatic Coating

Gen Boya 664 Genfloor Antistatic Coating ambalaj görseli

SPECIAL PERFORMANCE SYSTEMS · ANTISTATIC TOPCOAT

664

Genfloor Antistatic Coating

2K · Solvent-free epoxy · Antistatic

Solvent-free antistatic epoxy topcoat for areas with explosion risk and sensitive electronics.

A two-component, solvent-free, epoxy-based topcoat forming the wearing layer of the antistatic epoxy floor system. It conducts static charges to earth in a controlled way.

Technical Data

LIANT

Epoxy resin

COMPOSANTS

Two-component (2K)

POSITION DANS LE SYSTÈME

Antistatic topcoat

DENSITÉ

1.60 ± 0.1 kg/L

EXTRAIT SEC EN VOLUME

Solvent-free (~100%)

DILUTION

Do not thin

MÉTHODE D’APPLICATION

Notched trowel, squeegee, spiked roller

PRÉPARATION DE SURFACE

Milling / shot-blasting, moisture < 4%

RENDEMENT

—

RENDEMENT

—

RENDEMENT

—

RENDEMENT

—

SÉCHAGE

—

CONDITIONNEMENT

—

TEINTE

Produced on request in colours from the RAL colour chart.

DOCUMENTS TECHNIQUES

Utilisation et application

DOMAINES D’UTILISATION

Used on industrial floors, in hospitals, operating theatres, laboratories, production and storage areas, and in areas with sensitive electrical and electronic equipment and explosion risk.

 

PRÉPARATION DE SURFACE ET APPLICATION

The system is applied over 640 Genfloor Primer and 647 Conductive Primer. Mix components A and B with a low-speed mechanical mixer until homogeneous (at least 2–3 minutes) and apply the mix within its pot life. Spread with a squeegee and notched trowel and de-aerate with a spiked roller. Ambient and floor temperature must be between +10 °C and +30 °C and relative humidity below 80%; floor temperature must be kept at least 3 °C above the dew point.

 

DOMAINES D’APPLICATION

→ Pharmaceutical, Hospital and Laboratory

→ Electronics and ESD Areas

→ Aircraft Hangars and Defence Industry

 

Technical data are average values at 20 °C and 65% relative humidity. Coverage varies with surface roughness, application method and film thickness. Consult the Gen Boya technical team for project-specific system design.

POINTS FORTS

— Controlled dissipation of static electricity

— Safety in areas with explosion risk

— Seamless, hygienic surface

— Solvent-free

SYSTÈME RECOMMANDÉ

PRIMAIRE

640 Genfloor Primer + 647 Conductive Concrete Primer

Le bon système pour votre sol, avec l’équipe technique Genfloor.

Nos experts vous accompagnent à chaque étape : analyse du support, mesure d’humidité, choix du système et calcul de consommation.

bottom of page