A solvent-free, two-component, self-levelling, hygienic polyurethane floor coating with high mechanical strength. The flexibility of polyurethane gives superior resistance to impact and thermal shock.

Technical Data

LIANT

Polyurethane

COMPOSANTS

Two-component (2K)

POSITION DANS LE SYSTÈME

Self-levelling coating

DENSITÉ

1.35 ± 0.1 kg/L

EXTRAIT SEC EN VOLUME

Solvent-free (~100%)

DILUTION

Do not thin

MÉTHODE D’APPLICATION

Notched trowel, squeegee, spiked roller

PRÉPARATION DE SURFACE

Milling / shot-blasting, moisture < 4%

RENDEMENT

—

RENDEMENT

—

RENDEMENT

—

RENDEMENT

—

SÉCHAGE

—

CONDITIONNEMENT

—

TEINTE

Produced on request in colours from the RAL colour chart.

DOCUMENTS TECHNIQUES

Utilisation et application

DOMAINES D’UTILISATION

Can be applied in factories, cold stores, refrigerated vehicle bodies, shopping centres, workshops, aircraft hangars, schools, hospitals, the pharmaceutical and food sectors, laboratories and areas with heavy forklift traffic.

 

PRÉPARATION DE SURFACE ET APPLICATION

New concrete must be cured for at least 28 days; surface moisture must not exceed 4%. Remove weak surface layers, laitance, oil, curing compounds and old coating residues by milling, shot-blasting or diamond grinding; remove the dust with an industrial vacuum. Repair cracks and holes with epoxy repair mortar. Prime the surface with 640 Genfloor Primer. Mix components A and B with a low-speed mechanical mixer until homogeneous (at least 2–3 minutes) and apply the mix within its pot life. Spread with a squeegee and notched trowel and de-aerate with a spiked roller. Ambient and floor temperature must be between +10 °C and +30 °C and relative humidity below 80%; floor temperature must be kept at least 3 °C above the dew point.

 

DOMAINES D’APPLICATION

→ Food and Beverage Plants

 

Technical data are average values at 20 °C and 65% relative humidity. Coverage varies with surface roughness, application method and film thickness. Consult the Gen Boya technical team for project-specific system design.

POINTS FORTS

— Flexible; impact and thermal-shock resistance

— Suitable for cold stores

— Hygienic, seamless surface

— Solvent-free

SYSTÈME RECOMMANDÉ

PRIMAIRE

640 Genfloor Primer

COUCHES SUIVANTES

Where exposed to UV, complete with 834 Genfloor Polyurethane Topcoat.