top of page

Genfloor / Primers and Impregnations / 644 Genfloor Impregnation SF Sealer

Gen Boya 644 Genfloor Emprenye SF Sealer ambalaj görseli

PRIMERS AND IMPREGNATIONS · PRIMER / SEALER

644

Genfloor Impregnation SF Sealer

2K · Solvent-free epoxy · Sealer

Flexible, solvent-free epoxy concrete impregnation and adhesion bridge cured with modified polyamide.

A two-component, solvent-free concrete primer based on epoxy resin and cured with a modified polyamide hardener. With its low viscosity and flexible structure it acts as the binding component in the protection of concrete surfaces.

Technical Data

СВЯЗУЮЩЕЕ

Epoxy / modified polyamide

КОМПОНЕНТЫ

Two-component (2K)

МЕСТО В СИСТЕМЕ

Primer / sealer

ПЛОТНОСТЬ

1.10 ± 0.05 kg/L

СУХОЙ ОСТАТОК ПО ОБЪЁМУ

Solvent-free (~100%)

РАЗБАВЛЕНИЕ

Do not thin

СПОСОБ НАНЕСЕНИЯ

Roller, brush

ПОДГОТОВКА ПОВЕРХНОСТИ

Milling / shot-blasting, moisture < 4%

РАСХОД

—

РАСХОД

—

РАСХОД

—

РАСХОД

—

ВЫСЫХАНИЕ

—

УПАКОВКА

—

ЦВЕТ

Clear

ТЕХНИЧЕСКАЯ ДОКУМЕНТАЦИЯ

Применение и нанесение

ОБЛАСТИ ПРИМЕНЕНИЯ

Used before epoxy and polyurethane topcoats to wet the concrete surface and provide a good adhesion bridge.

 

ПОДГОТОВКА ПОВЕРХНОСТИ И НАНЕСЕНИЕ

New concrete must be cured for at least 28 days; surface moisture must not exceed 4%. Remove weak surface layers, laitance, oil, curing compounds and old coating residues by milling, shot-blasting or diamond grinding; remove the dust with an industrial vacuum. Repair cracks and holes with epoxy repair mortar. Mix components A and B with a low-speed mechanical mixer until homogeneous (at least 2–3 minutes) and apply the mix within its pot life. Apply by roller as a thin, even film. Ambient and floor temperature must be between +10 °C and +30 °C and relative humidity below 80%; floor temperature must be kept at least 3 °C above the dew point.

 

 

Technical data are average values at 20 °C and 65% relative humidity. Coverage varies with surface roughness, application method and film thickness. Consult the Gen Boya technical team for project-specific system design.

КЛЮЧЕВЫЕ ПРЕИМУЩЕСТВА

— Flexible structure

— Low viscosity, good wetting

— Adhesion bridge for epoxy and polyurethane coats

— Solvent-free

РЕКОМЕНДАЦИЯ ПО СИСТЕМЕ

—

Правильная система для вашего пола — с техническими специалистами Genfloor.

Наши эксперты сопровождают проект на каждом этапе: анализ основания, замер влажности, выбор системы и расчёт расхода.

bottom of page