top of page

Genfloor / Special Performance Systems / 647 Genfloor Conductive Concrete Primer

Gen Boya 647 Genfloor Conductive Concrete Primer ambalaj görseli

SPECIAL PERFORMANCE SYSTEMS · CONDUCTIVE INTERMEDIATE PRIMER

647

Genfloor Conductive Concrete Primer

2K · Solvent-free epoxy · Conductive

Solvent-free, high-strength conductive epoxy primer for antistatic and ESD floor systems.

A solvent-free, high-strength, epoxy-based conductive floor primer. Together with the antistatic topcoat it forms an earthed conductive floor system.

Technical Data

СВЯЗУЮЩЕЕ

Epoxy resin

КОМПОНЕНТЫ

Two-component (2K)

МЕСТО В СИСТЕМЕ

Conductive intermediate primer

ПЛОТНОСТЬ

1.10 ± 0.05 kg/L

СУХОЙ ОСТАТОК ПО ОБЪЁМУ

Solvent-free (~100%)

РАЗБАВЛЕНИЕ

Do not thin

СПОСОБ НАНЕСЕНИЯ

Roller

ПОДГОТОВКА ПОВЕРХНОСТИ

Milling / shot-blasting, moisture < 4%

РАСХОД

—

РАСХОД

—

РАСХОД

—

РАСХОД

—

ВЫСЫХАНИЕ

—

УПАКОВКА

—

ЦВЕТ

Black

ТЕХНИЧЕСКАЯ ДОКУМЕНТАЦИЯ

Применение и нанесение

ОБЛАСТИ ПРИМЕНЕНИЯ

Applied in aircraft hangars, automotive plants, defence manufacturing facilities, healthcare laboratories, paint shops, electrical and electronics laboratories, and areas with sensitive electronic equipment and a high explosion risk.

 

ПОДГОТОВКА ПОВЕРХНОСТИ И НАНЕСЕНИЕ

New concrete must be cured for at least 28 days; surface moisture must not exceed 4%. Remove weak surface layers, laitance, oil, curing compounds and old coating residues by milling, shot-blasting or diamond grinding; remove the dust with an industrial vacuum. Repair cracks and holes with epoxy repair mortar. Prime the surface with 640 Genfloor Primer and lay copper strips for earthing. Mix components A and B with a low-speed mechanical mixer until homogeneous (at least 2–3 minutes) and apply the mix within its pot life. Apply by roller. Ambient and floor temperature must be between +10 °C and +30 °C and relative humidity below 80%; floor temperature must be kept at least 3 °C above the dew point.

 

ОБЛАСТИ ПРИМЕНЕНИЯ

→ Electronics and ESD Areas

→ Aircraft Hangars and Defence Industry

 

Technical data are average values at 20 °C and 65% relative humidity. Coverage varies with surface roughness, application method and film thickness. Consult the Gen Boya technical team for project-specific system design.

КЛЮЧЕВЫЕ ПРЕИМУЩЕСТВА

— Conductive interlayer

— Carrier primer of antistatic systems

— High strength

— Solvent-free

РЕКОМЕНДАЦИЯ ПО СИСТЕМЕ

ГРУНТ

640 Genfloor Primer

ПОСЛЕДУЮЩИЕ СЛОИ

664 Genfloor Antistatic Coating

Правильная система для вашего пола — с техническими специалистами Genfloor.

Наши эксперты сопровождают проект на каждом этапе: анализ основания, замер влажности, выбор системы и расчёт расхода.

bottom of page