top of page

Genfloor / Epoxy Topcoats / 659 Genfloor Topcoat SF

Gen Boya 659 Genfloor Topcoat SF ambalaj görseli

EPOXY TOPCOATS · TOPCOAT

659

Genfloor Topcoat SF

2K · Solvent-free epoxy · Topcoat

Hygienic, smooth-finish, solvent-free epoxy floor paint for pedestrian and light vehicle traffic.

A two-component, hygienic, solvent-free epoxy topcoat with a smooth finish, applied on concrete and suitable for floors with pedestrian and light vehicle traffic.

Technical Data

СВЯЗУЮЩЕЕ

Epoxy resin

КОМПОНЕНТЫ

Two-component (2K)

МЕСТО В СИСТЕМЕ

Topcoat

ПЛОТНОСТЬ

1.45 ± 0.1 kg/L

СУХОЙ ОСТАТОК ПО ОБЪЁМУ

Solvent-free (~100%)

БЛЕСК / ВИД

Gloss

ТЕОРЕТИЧЕСКИЙ РАСХОД

3 m²/kg (single coat)

СООТНОШЕНИЕ СМЕШИВАНИЯ

4 : 1 by weight (A : B)

РАЗБАВЛЕНИЕ

Do not thin

СПОСОБ НАНЕСЕНИЯ

Roller, trowel, squeegee

ПОДГОТОВКА ПОВЕРХНОСТИ

Milling / shot-blasting, moisture < 4%

РАСХОД

—

ВЫСЫХАНИЕ

Dust dry 6–8 h · Touch dry 10–12 h · Full cure 7 days (23 °C)

УПАКОВКА

20 kg kit (16 kg A + 4 kg B)

ЦВЕТ

Produced on request in colours from the RAL colour chart.

ТЕХНИЧЕСКАЯ ДОКУМЕНТАЦИЯ

Применение и нанесение

ОБЛАСТИ ПРИМЕНЕНИЯ

Used in production and storage areas with forklift traffic, loading ramps, supermarkets, multi-storey and underground car parks, exhibition halls.

 

ПОДГОТОВКА ПОВЕРХНОСТИ И НАНЕСЕНИЕ

New concrete must be cured for at least 28 days; surface moisture must not exceed 4%. Remove weak surface layers, laitance, oil, curing compounds and old coating residues by milling, shot-blasting or diamond grinding; remove the dust with an industrial vacuum. Repair cracks and holes with epoxy repair mortar. Prime the surface with 640 Genfloor Primer; apply the topcoat within 24 hours of priming. Mix components A and B with a low-speed mechanical mixer until homogeneous (at least 2–3 minutes) and apply the mix within its pot life. Apply by roller, trowel or squeegee. Ambient and floor temperature must be between +10 °C and +30 °C and relative humidity below 80%; floor temperature must be kept at least 3 °C above the dew point.

 

ОБЛАСТИ ПРИМЕНЕНИЯ

→ Factories and Production Plants

→ Car Parks and Ramps

 

Technical data are average values at 20 °C and 65% relative humidity. Coverage varies with surface roughness, application method and film thickness. Consult the Gen Boya technical team for project-specific system design.

КЛЮЧЕВЫЕ ПРЕИМУЩЕСТВА

— Smooth, hygienic finish

— Solvent-free, low odour

— Easy to clean

— RAL colour options

РЕКОМЕНДАЦИЯ ПО СИСТЕМЕ

ГРУНТ

640 Genfloor Primer

Правильная система для вашего пола — с техническими специалистами Genfloor.

Наши эксперты сопровождают проект на каждом этапе: анализ основания, замер влажности, выбор системы и расчёт расхода.