Genfloor / Special Performance Systems / 664 Genfloor Antistatic Coating

Gen Boya 664 Genfloor Antistatic Coating ambalaj görseli

SPECIAL PERFORMANCE SYSTEMS · ANTISTATIC TOPCOAT

664

Genfloor Antistatic Coating

2K · Solvent-free epoxy · Antistatic

Solvent-free antistatic epoxy topcoat for areas with explosion risk and sensitive electronics.

A two-component, solvent-free, epoxy-based topcoat forming the wearing layer of the antistatic epoxy floor system. It conducts static charges to earth in a controlled way.

Technical Data

СВЯЗУЮЩЕЕ

Epoxy resin

КОМПОНЕНТЫ

Two-component (2K)

МЕСТО В СИСТЕМЕ

Antistatic topcoat

ПЛОТНОСТЬ

1.60 ± 0.1 kg/L

СУХОЙ ОСТАТОК ПО ОБЪЁМУ

Solvent-free (~100%)

РАЗБАВЛЕНИЕ

Do not thin

СПОСОБ НАНЕСЕНИЯ

Notched trowel, squeegee, spiked roller

ПОДГОТОВКА ПОВЕРХНОСТИ

Milling / shot-blasting, moisture < 4%

РАСХОД

—

РАСХОД

—

РАСХОД

—

РАСХОД

—

ВЫСЫХАНИЕ

—

УПАКОВКА

—

ЦВЕТ

Produced on request in colours from the RAL colour chart.

ТЕХНИЧЕСКАЯ ДОКУМЕНТАЦИЯ

Применение и нанесение

ОБЛАСТИ ПРИМЕНЕНИЯ

Used on industrial floors, in hospitals, operating theatres, laboratories, production and storage areas, and in areas with sensitive electrical and electronic equipment and explosion risk.

 

ПОДГОТОВКА ПОВЕРХНОСТИ И НАНЕСЕНИЕ

The system is applied over 640 Genfloor Primer and 647 Conductive Primer. Mix components A and B with a low-speed mechanical mixer until homogeneous (at least 2–3 minutes) and apply the mix within its pot life. Spread with a squeegee and notched trowel and de-aerate with a spiked roller. Ambient and floor temperature must be between +10 °C and +30 °C and relative humidity below 80%; floor temperature must be kept at least 3 °C above the dew point.

 

ОБЛАСТИ ПРИМЕНЕНИЯ

→ Pharmaceutical, Hospital and Laboratory

→ Electronics and ESD Areas

→ Aircraft Hangars and Defence Industry

 

Technical data are average values at 20 °C and 65% relative humidity. Coverage varies with surface roughness, application method and film thickness. Consult the Gen Boya technical team for project-specific system design.

КЛЮЧЕВЫЕ ПРЕИМУЩЕСТВА

— Controlled dissipation of static electricity

— Safety in areas with explosion risk

— Seamless, hygienic surface

— Solvent-free

РЕКОМЕНДАЦИЯ ПО СИСТЕМЕ

ГРУНТ

640 Genfloor Primer + 647 Conductive Concrete Primer

Правильная система для вашего пола — с техническими специалистами Genfloor.

Наши эксперты сопровождают проект на каждом этапе: анализ основания, замер влажности, выбор системы и расчёт расхода.