top of page

Genfloor / Special Performance Systems / 667 Genfloor Fire-Retardant Coating

Gen Boya 667 Genfloor Fire-Retardant Coating ambalaj görseli

SPECIAL PERFORMANCE SYSTEMS · FIRE-RETARDANT TOPCOAT

667

Genfloor Fire-Retardant Coating

2K · Solvent-free epoxy · Fire-retardant

Self-levelling, solvent-free fire-retardant epoxy floor coating for facilities where fire safety is required.

A solvent-free, self-levelling, epoxy-based fire-retardant floor coating. It forms a protective floor system in production and storage areas where fire safety is a priority.

Technical Data

СВЯЗУЮЩЕЕ

Epoxy resin

КОМПОНЕНТЫ

Two-component (2K)

МЕСТО В СИСТЕМЕ

Fire-retardant topcoat

ПЛОТНОСТЬ

1.65 ± 0.1 kg/L

СУХОЙ ОСТАТОК ПО ОБЪЁМУ

Solvent-free (~100%)

РАЗБАВЛЕНИЕ

Do not thin

СПОСОБ НАНЕСЕНИЯ

Notched trowel, squeegee, spiked roller

ПОДГОТОВКА ПОВЕРХНОСТИ

Milling / shot-blasting, moisture < 4%

РАСХОД

—

РАСХОД

—

РАСХОД

—

РАСХОД

—

ВЫСЫХАНИЕ

—

УПАКОВКА

—

ЦВЕТ

Produced on request in colours from the RAL colour chart.

ТЕХНИЧЕСКАЯ ДОКУМЕНТАЦИЯ

Применение и нанесение

ОБЛАСТИ ПРИМЕНЕНИЯ

Used in the cosmetics and pharmaceutical, metalworking and food industries, catering plants, manufacturing and assembly, offshore platforms, paint factories, textiles, cold stores, the automotive industry, dairies and farms.

 

ПОДГОТОВКА ПОВЕРХНОСТИ И НАНЕСЕНИЕ

New concrete must be cured for at least 28 days; surface moisture must not exceed 4%. Remove weak surface layers, laitance, oil, curing compounds and old coating residues by milling, shot-blasting or diamond grinding; remove the dust with an industrial vacuum. Repair cracks and holes with epoxy repair mortar. Prime the surface with 640 Genfloor Primer. Mix components A and B with a low-speed mechanical mixer until homogeneous (at least 2–3 minutes) and apply the mix within its pot life. Spread with a squeegee and notched trowel. Ambient and floor temperature must be between +10 °C and +30 °C and relative humidity below 80%; floor temperature must be kept at least 3 °C above the dew point.

 

 

Technical data are average values at 20 °C and 65% relative humidity. Coverage varies with surface roughness, application method and film thickness. Consult the Gen Boya technical team for project-specific system design.

КЛЮЧЕВЫЕ ПРЕИМУЩЕСТВА

— Fire-retardant formulation

— Self-levelling structure

— Mechanical resistance

— Solvent-free

РЕКОМЕНДАЦИЯ ПО СИСТЕМЕ

ГРУНТ

640 Genfloor Primer

Правильная система для вашего пола — с техническими специалистами Genfloor.

Наши эксперты сопровождают проект на каждом этапе: анализ основания, замер влажности, выбор системы и расчёт расхода.

bottom of page