Genfloor / Polyurethane Systems / 832 Genfloor Polyurethane Floor Basecoat

POLYURETHANE SYSTEMS · SELF-LEVELLING COATING
832
Genfloor Polyurethane Floor Basecoat
2K · Solvent-free PU · Self-levelling
Solvent-free, hygienic polyurethane floor coating for cold stores and heavy forklift traffic.
A solvent-free, two-component, self-levelling, hygienic polyurethane floor coating with high mechanical strength. The flexibility of polyurethane gives superior resistance to impact and thermal shock.
Technical Data
СВЯЗУЮЩЕЕ
Polyurethane
КОМПОНЕНТЫ
Two-component (2K)
МЕСТО В СИСТЕМЕ
Self-levelling coating
ПЛОТНОСТЬ
1.35 ± 0.1 kg/L
СУХОЙ ОСТАТОК ПО ОБЪЁМУ
Solvent-free (~100%)
РАЗБАВЛЕНИЕ
Do not thin
СПОСОБ НАНЕСЕНИЯ
Notched trowel, squeegee, spiked roller
ПОДГОТОВКА ПОВЕРХНОСТИ
Milling / shot-blasting, moisture < 4%
РАСХОД
—
РАСХОД
—
РАСХОД
—
РАСХОД
—
ВЫСЫХАНИЕ
—
УПАКОВКА
—
ЦВЕТ
Produced on request in colours from the RAL colour chart.
ТЕХНИЧЕСКАЯ ДОКУМЕНТАЦИЯ
Применение и нанесение
ОБЛАСТИ ПРИМЕНЕНИЯ
Can be applied in factories, cold stores, refrigerated vehicle bodies, shopping centres, workshops, aircraft hangars, schools, hospitals, the pharmaceutical and food sectors, laboratories and areas with heavy forklift traffic.
ПОДГОТОВКА ПОВЕРХНОСТИ И НАНЕСЕНИЕ
New concrete must be cured for at least 28 days; surface moisture must not exceed 4%. Remove weak surface layers, laitance, oil, curing compounds and old coating residues by milling, shot-blasting or diamond grinding; remove the dust with an industrial vacuum. Repair cracks and holes with epoxy repair mortar. Prime the surface with 640 Genfloor Primer. Mix components A and B with a low-speed mechanical mixer until homogeneous (at least 2–3 minutes) and apply the mix within its pot life. Spread with a squeegee and notched trowel and de-aerate with a spiked roller. Ambient and floor temperature must be between +10 °C and +30 °C and relative humidity below 80%; floor temperature must be kept at least 3 °C above the dew point.
ОБЛАСТИ ПРИМЕНЕНИЯ
Technical data are average values at 20 °C and 65% relative humidity. Coverage varies with surface roughness, application method and film thickness. Consult the Gen Boya technical team for project-specific system design.
КЛЮЧЕВЫЕ ПРЕИМУЩЕСТВА
— Flexible; impact and thermal-shock resistance
— Suitable for cold stores
— Hygienic, seamless surface
— Solvent-free
РЕКОМЕНДАЦИЯ ПО СИСТЕМЕ
ГРУНТ
640 Genfloor Primer
ПОСЛЕДУЮЩИЕ СЛОИ
Where exposed to UV, complete with 834 Genfloor Polyurethane Topcoat.