top of page

Genfloor / Primers and Impregnations / 641 Genfloor Ceramic Surface Primer

Gen Boya 641 Genfloor Seramik Yüzey Astarı ambalaj görseli

PRIMERS AND IMPREGNATIONS · CERAMIC TRANSITION PRIMER

641

Genfloor Ceramic Surface Primer

2K · Solvent-free epoxy · Ceramic transition

Solvent-free epoxy transition primer for ceramic tiles and non-absorbent surfaces.

A two-component transition primer based on solvent-free epoxy resin, developed for non-absorbent ceramic surfaces. Applied over ceramic tiles, it acts as an adhesion bridge for subsequent epoxy and polyurethane coatings, allowing existing tiles to be coated without removal.

Technical Data

BINDER

Epoxy resin

COMPONENTS

Two-component (2K)

POSITION IN SYSTEM

Ceramic transition primer

DENSITY

1.06 ± 0.05 kg/L

VOLUME SOLIDS

Solvent-free (~100%)

THEORETICAL COVERAGE

50–100 g/m² (max. 100 µm)

MIXING RATIO

7 : 3 by weight (A : B)

THINNING

Do not thin

APPLICATION METHOD

Roller, airless spray

SURFACE PREPARATION

Clean, grease-free, dry ceramic tiles

COVERAGE

—

COVERAGE

—

DRYING

Dust dry 3–4 h · Touch dry 8–10 h · Full cure 7 days (23 °C)

PACKAGING

20 kg kit (14 kg A + 6 kg B)

COLOUR

—

TECHNICAL DOCUMENTS

Use and Application

AREAS OF USE

Used on ceramic tiles indoors and outdoors: in hygienic environments such as hospitals and laboratories, in the food, pharmaceutical and paint industries, industrial kitchens, factories, warehouses, terminals, shopping centres and schools.

 

SURFACE PREPARATION AND APPLICATION

Ceramic tiles and joints must be dry and free from loose parts, dust, oil, silicone, detergent and release agents. Mix components A and B with a low-speed mechanical mixer until homogeneous (at least 2–3 minutes) and apply the mix within its pot life. Apply by roller or airless spray; broadcast dry silica sand into the wet film and sweep off the excess once dry. Apply the following coats within 24 hours at the latest. Ambient and floor temperature must be between +10 °C and +30 °C and relative humidity below 80%; floor temperature must be kept at least 3 °C above the dew point.

 

APPLICATION AREAS

→ Pharmaceutical, Hospital and Laboratory

 

Technical data are average values at 20 °C and 65% relative humidity. Coverage varies with surface roughness, application method and film thickness. Consult the Gen Boya technical team for project-specific system design.

KEY FEATURES

— Coating without removing the tiles

— Strong adhesion to non-absorbent surfaces

— Rough interface with silica broadcast

— Compatible with epoxy and polyurethane systems

SYSTEM RECOMMENDATION

SUBSEQUENT COATS

Complete with 659 Genfloor Topcoat SF, 660 Self-Levelling or 665 Chem Coating.

The right system for your floor, with the Genfloor technical team.

Our experts support you at every stage of your project with floor analysis, moisture measurement, system selection and consumption calculation.

bottom of page