top of page

Genfloor / Primers and Impregnations / 643 Genfloor Primer Impregnation SB

Gen Boya 643 Genfloor Primer Emprenye SB ambalaj görseli

PRIMERS AND IMPREGNATIONS · IMPREGNATING PRIMER

643

Genfloor Primer Impregnation SB

2K · Solvent-borne epoxy · Impregnation

Solvent-borne, low-viscosity epoxy impregnating primer that penetrates deep into concrete hairline cracks.

A high-solids, two-component, low-viscosity impregnating concrete primer made of solvent-borne epoxy resin and hardener. Its solvent-borne nature allows it to penetrate well into the hairline cracks of concrete.

Technical Data

BINDER

Epoxy resin

COMPONENTS

Two-component (2K)

POSITION IN SYSTEM

Impregnating primer

DENSITY

1.01 ± 0.05 kg/L

VOLUME SOLIDS

50%

THINNING

016 Gen Epoxy Thinner

APPLICATION METHOD

Roller, brush

SURFACE PREPARATION

Milling / shot-blasting, moisture < 4%

COVERAGE

—

COVERAGE

—

COVERAGE

—

COVERAGE

—

DRYING

—

PACKAGING

—

COLOUR

Clear

TECHNICAL DOCUMENTS

Use and Application

AREAS OF USE

Used on cured concrete, terrazzo, ceramic tiles and metal surfaces to give floor coatings strong adhesion.

 

SURFACE PREPARATION AND APPLICATION

New concrete must be cured for at least 28 days; surface moisture must not exceed 4%. Remove weak surface layers, laitance, oil, curing compounds and old coating residues by milling, shot-blasting or diamond grinding; remove the dust with an industrial vacuum. Repair cracks and holes with epoxy repair mortar. Mix components A and B with a low-speed mechanical mixer until homogeneous (at least 2–3 minutes) and apply the mix within its pot life. Apply by roller or brush until the surface is saturated. Ambient and floor temperature must be between +10 °C and +30 °C and relative humidity below 80%; floor temperature must be kept at least 3 °C above the dew point.

 

 

Technical data are average values at 20 °C and 65% relative humidity. Coverage varies with surface roughness, application method and film thickness. Consult the Gen Boya technical team for project-specific system design.

KEY FEATURES

— Low viscosity, high penetration

— Deep penetration into hairline cracks

— Consolidates the surface against dusting

— Fully compatible with epoxy systems

SYSTEM RECOMMENDATION

SUBSEQUENT COATS

Continue with 622 Genfloor Topcoat SB or solvent-free Genfloor topcoats.

The right system for your floor, with the Genfloor technical team.

Our experts support you at every stage of your project with floor analysis, moisture measurement, system selection and consumption calculation.