Genfloor / Self-Levelling Systems / 657 Genfloor Self Levelling Basecoat

SELF-LEVELLING SYSTEMS · SELF-LEVELLING BASECOAT
657
Genfloor Self Levelling Basecoat
2K · Solvent-free epoxy · Basecoat
Solvent-free epoxy self-levelling basecoat to build the required thickness between primer and topcoat.
A two-component, solvent-free epoxy self-levelling basecoat. It is designed to be applied between primer and topcoat to reach the required film thickness, optimising the total cost of the system.
Technical Data
BINDER
Epoxy resin
COMPONENTS
Multi-component (A + B + filler)
POSITION IN SYSTEM
Self-levelling basecoat
DENSITY
1.75 ± 0.1 kg/L
VOLUME SOLIDS
Solvent-free (~100%)
THEORETICAL COVERAGE
1.8 kg/m² per 1 mm thickness
THINNING
Do not thin
APPLICATION METHOD
Notched trowel, squeegee, spiked roller
SURFACE PREPARATION
Milling / shot-blasting, moisture < 4%
COVERAGE
—
COVERAGE
—
COVERAGE
—
DRYING
Dust dry 3–4 h · Touch dry 10–12 h · Full cure 7 days
PACKAGING
25 kg kit (10 kg A + 2.5 kg B + 12.5 kg filler)
COLOUR
—
TECHNICAL DOCUMENTS
Use and Application
AREAS OF USE
Used in self-levelling floor systems between primer and topcoat, in production, storage and logistics areas requiring thickness and mechanical strength.
SURFACE PREPARATION AND APPLICATION
New concrete must be cured for at least 28 days; surface moisture must not exceed 4%. Remove weak surface layers, laitance, oil, curing compounds and old coating residues by milling, shot-blasting or diamond grinding; remove the dust with an industrial vacuum. Repair cracks and holes with epoxy repair mortar. Prime the surface with 640 Genfloor Primer. Mix components A and B with a low-speed mechanical mixer until homogeneous (at least 2–3 minutes) and apply the mix within its pot life. Pour the mix onto the floor, spread to the required thickness with a notched trowel or squeegee and de-aerate with a spiked roller. Ambient and floor temperature must be between +10 °C and +30 °C and relative humidity below 80%; floor temperature must be kept at least 3 °C above the dew point.
APPLICATION AREAS
→ Factories and Production Plants
→ Warehouses and Logistics Centres
Technical data are average values at 20 °C and 65% relative humidity. Coverage varies with surface roughness, application method and film thickness. Consult the Gen Boya technical team for project-specific system design.
KEY FEATURES
— Self-levelling structure
— Optimises system cost
— High mechanical strength
— Solvent-free
SYSTEM RECOMMENDATION
PRIMER
640 Genfloor Primer
SUBSEQUENT COATS
660 Genfloor Self Levelling Topcoat