A two-component, solvent-free epoxy topcoat giving an orange-peel finish. Its textured surface reduces the risk of slipping while offering high surface hardness, water and chemical resistance and easy cleaning.

Technical Data

BINDER

Epoxy resin

COMPONENTS

Two-component (2K)

POSITION IN SYSTEM

Textured topcoat

DENSITY

1.80 ± 0.1 kg/L

VOLUME SOLIDS

Solvent-free (~100%)

GLOSS / APPEARANCE

Orange-peel (textured) finish

THEORETICAL COVERAGE

400 g/m² (200–225 µm dry film)

MIXING RATIO

9 : 1 by weight (A : B)

THINNING

Do not thin

APPLICATION METHOD

Roller, brush

SURFACE PREPARATION

Milling / shot-blasting, moisture < 4%

COVERAGE

—

DRYING

Dust dry 6–8 h · Touch dry 24 h · Full cure 7 days

PACKAGING

20 kg kit (18 kg A + 2 kg B)

COLOUR

Produced on request in colours from the RAL colour chart.

TECHNICAL DOCUMENTS

Use and Application

AREAS OF USE

Used where mechanical resistance is required: production and storage areas with forklift traffic, loading ramps, supermarkets, multi-storey and underground car parks, exhibition halls.

 

SURFACE PREPARATION AND APPLICATION

New concrete must be cured for at least 28 days; surface moisture must not exceed 4%. Remove weak surface layers, laitance, oil, curing compounds and old coating residues by milling, shot-blasting or diamond grinding; remove the dust with an industrial vacuum. Repair cracks and holes with epoxy repair mortar. Prime the surface with 640 Genfloor Primer; repair cracks and pits with epoxy filler. Mix components A and B with a low-speed mechanical mixer until homogeneous (at least 2–3 minutes) and apply the mix within its pot life. Apply by brush or roller. Ambient and floor temperature must be between +10 °C and +30 °C and relative humidity below 80%; floor temperature must be kept at least 3 °C above the dew point.

 

APPLICATION AREAS

→ Warehouses and Logistics Centres

→ Car Parks and Ramps

 

Technical data are average values at 20 °C and 65% relative humidity. Coverage varies with surface roughness, application method and film thickness. Consult the Gen Boya technical team for project-specific system design.

KEY FEATURES

— Textured (orange-peel) surface, slip resistance

— High surface hardness

— Water and chemical resistance

— Easy to clean

SYSTEM RECOMMENDATION

PRIMER

640 Genfloor Primer

The right system for your floor, with the Genfloor technical team.

Our experts support you at every stage of your project with floor analysis, moisture measurement, system selection and consumption calculation.