top of page

Genfloor / Special Performance Systems / 664 Genfloor Antistatic Coating

Gen Boya 664 Genfloor Antistatic Coating ambalaj görseli

SPECIAL PERFORMANCE SYSTEMS · ANTISTATIC TOPCOAT

664

Genfloor Antistatic Coating

2K · Solvent-free epoxy · Antistatic

Solvent-free antistatic epoxy topcoat for areas with explosion risk and sensitive electronics.

A two-component, solvent-free, epoxy-based topcoat forming the wearing layer of the antistatic epoxy floor system. It conducts static charges to earth in a controlled way.

Technical Data

BINDER

Epoxy resin

COMPONENTS

Two-component (2K)

POSITION IN SYSTEM

Antistatic topcoat

DENSITY

1.60 ± 0.1 kg/L

VOLUME SOLIDS

Solvent-free (~100%)

THINNING

Do not thin

APPLICATION METHOD

Notched trowel, squeegee, spiked roller

SURFACE PREPARATION

Milling / shot-blasting, moisture < 4%

COVERAGE

—

COVERAGE

—

COVERAGE

—

COVERAGE

—

DRYING

—

PACKAGING

—

COLOUR

Produced on request in colours from the RAL colour chart.

TECHNICAL DOCUMENTS

Use and Application

AREAS OF USE

Used on industrial floors, in hospitals, operating theatres, laboratories, production and storage areas, and in areas with sensitive electrical and electronic equipment and explosion risk.

 

SURFACE PREPARATION AND APPLICATION

The system is applied over 640 Genfloor Primer and 647 Conductive Primer. Mix components A and B with a low-speed mechanical mixer until homogeneous (at least 2–3 minutes) and apply the mix within its pot life. Spread with a squeegee and notched trowel and de-aerate with a spiked roller. Ambient and floor temperature must be between +10 °C and +30 °C and relative humidity below 80%; floor temperature must be kept at least 3 °C above the dew point.

 

APPLICATION AREAS

→ Pharmaceutical, Hospital and Laboratory

→ Electronics and ESD Areas

→ Aircraft Hangars and Defence Industry

 

Technical data are average values at 20 °C and 65% relative humidity. Coverage varies with surface roughness, application method and film thickness. Consult the Gen Boya technical team for project-specific system design.

KEY FEATURES

— Controlled dissipation of static electricity

— Safety in areas with explosion risk

— Seamless, hygienic surface

— Solvent-free

SYSTEM RECOMMENDATION

PRIMER

640 Genfloor Primer + 647 Conductive Concrete Primer

The right system for your floor, with the Genfloor technical team.

Our experts support you at every stage of your project with floor analysis, moisture measurement, system selection and consumption calculation.

bottom of page