top of page

Genfloor / Primers and Impregnations / 640 Genfloor Primer

Gen Boya 640 Genfloor Primer ambalaj görseli

PRIMERS AND IMPREGNATIONS · PRIMER / IMPREGNATION

640

Genfloor Primer

2K · Solvent-free epoxy · Primer

Solvent-free, two-component, clear epoxy concrete primer and impregnation.

A 100% solids (solvent-free), two-component, clear concrete primer made of epoxy resin and hardener. Its excellent penetration fills the capillary pores of concrete, increases surface strength and forms a strong adhesion bridge for subsequent epoxy and polyurethane coats.

Technical Data

LIGANTE

Epoxy resin

COMPONENTES

Two-component (2K)

POSICIÓN EN EL SISTEMA

Primer / impregnation

DENSIDAD

1.05 ± 0.05 kg/L

SÓLIDOS EN VOLUMEN

Solvent-free (~100%)

RENDIMIENTO TEÓRICO

250–500 g/m² (depending on substrate)

PROPORCIÓN DE MEZCLA

2 : 1 by weight (A : B)

DILUCIÓN

Do not thin

MÉTODO DE APLICACIÓN

Roller, brush; trowel for sand-filled levelling

PREPARACIÓN DE SUPERFICIE

Milling / shot-blasting, moisture < 4%

RENDIMIENTO

—

RENDIMIENTO

—

SECADO

Dust dry 3–4 h · Touch dry 8–10 h · Full cure 7 days (23 °C)

ENVASE

15 kg kit (10 kg A + 5 kg B)

COLOR

Clear

DOCUMENTOS TÉCNICOS

Uso y aplicación

USOS

Used as a primer coat on cured concrete, terrazzo, ceramic tiles and metal to give floor coatings strong adhesion.

 

PREPARACIÓN DE SUPERFICIE Y APLICACIÓN

New concrete must be cured for at least 28 days; surface moisture must not exceed 4%. Remove weak surface layers, laitance, oil, curing compounds and old coating residues by milling, shot-blasting or diamond grinding; remove the dust with an industrial vacuum. Repair cracks and holes with epoxy repair mortar. Mix components A and B with a low-speed mechanical mixer until homogeneous (at least 2–3 minutes) and apply the mix within its pot life. Apply the primer by roller or brush so that it impregnates the surface; on rough surfaces it can be mixed 1:1 with 0.2–0.5 mm silica sand and used as a trowelled levelling coat. Apply the next coat within 24 hours at the latest. Ambient and floor temperature must be between +10 °C and +30 °C and relative humidity below 80%; floor temperature must be kept at least 3 °C above the dew point.

 

ÁREAS DE APLICACIÓN

→ Factories and Production Plants

→ Warehouses and Logistics Centres

→ Car Parks and Ramps

→ Food and Beverage Plants

→ Pharmaceutical, Hospital and Laboratory

→ Electronics and ESD Areas

→ Aircraft Hangars and Defence Industry

 

Technical data are average values at 20 °C and 65% relative humidity. Coverage varies with surface roughness, application method and film thickness. Consult the Gen Boya technical team for project-specific system design.

CARACTERÍSTICAS PRINCIPALES

— Solvent-free, low-odour formulation

— Deep penetration into concrete capillaries

— Increases surface strength

— Can be used with silica sand as a levelling / scratch coat

— Compatible with all Genfloor epoxy and polyurethane systems

SISTEMA RECOMENDADO

CAPAS SIGUIENTES

Continue with 657 / 660 Self-Levelling, 659 Genfloor Topcoat SF or 655 HB Flex.

El sistema adecuado para su suelo, con el equipo técnico de Genfloor.

Nuestros expertos le acompañan en cada fase del proyecto: análisis del suelo, medición de humedad, selección del sistema y cálculo de consumo.

bottom of page