top of page

Genfloor / Primers and Impregnations / 641 Genfloor Ceramic Surface Primer

Gen Boya 641 Genfloor Seramik Yüzey Astarı ambalaj görseli

PRIMERS AND IMPREGNATIONS · CERAMIC TRANSITION PRIMER

641

Genfloor Ceramic Surface Primer

2K · Solvent-free epoxy · Ceramic transition

Solvent-free epoxy transition primer for ceramic tiles and non-absorbent surfaces.

A two-component transition primer based on solvent-free epoxy resin, developed for non-absorbent ceramic surfaces. Applied over ceramic tiles, it acts as an adhesion bridge for subsequent epoxy and polyurethane coatings, allowing existing tiles to be coated without removal.

Technical Data

LIGANTE

Epoxy resin

COMPONENTES

Two-component (2K)

POSICIÓN EN EL SISTEMA

Ceramic transition primer

DENSIDAD

1.06 ± 0.05 kg/L

SÓLIDOS EN VOLUMEN

Solvent-free (~100%)

RENDIMIENTO TEÓRICO

50–100 g/m² (max. 100 µm)

PROPORCIÓN DE MEZCLA

7 : 3 by weight (A : B)

DILUCIÓN

Do not thin

MÉTODO DE APLICACIÓN

Roller, airless spray

PREPARACIÓN DE SUPERFICIE

Clean, grease-free, dry ceramic tiles

RENDIMIENTO

—

RENDIMIENTO

—

SECADO

Dust dry 3–4 h · Touch dry 8–10 h · Full cure 7 days (23 °C)

ENVASE

20 kg kit (14 kg A + 6 kg B)

COLOR

—

DOCUMENTOS TÉCNICOS

Uso y aplicación

USOS

Used on ceramic tiles indoors and outdoors: in hygienic environments such as hospitals and laboratories, in the food, pharmaceutical and paint industries, industrial kitchens, factories, warehouses, terminals, shopping centres and schools.

 

PREPARACIÓN DE SUPERFICIE Y APLICACIÓN

Ceramic tiles and joints must be dry and free from loose parts, dust, oil, silicone, detergent and release agents. Mix components A and B with a low-speed mechanical mixer until homogeneous (at least 2–3 minutes) and apply the mix within its pot life. Apply by roller or airless spray; broadcast dry silica sand into the wet film and sweep off the excess once dry. Apply the following coats within 24 hours at the latest. Ambient and floor temperature must be between +10 °C and +30 °C and relative humidity below 80%; floor temperature must be kept at least 3 °C above the dew point.

 

ÁREAS DE APLICACIÓN

→ Pharmaceutical, Hospital and Laboratory

 

Technical data are average values at 20 °C and 65% relative humidity. Coverage varies with surface roughness, application method and film thickness. Consult the Gen Boya technical team for project-specific system design.

CARACTERÍSTICAS PRINCIPALES

— Coating without removing the tiles

— Strong adhesion to non-absorbent surfaces

— Rough interface with silica broadcast

— Compatible with epoxy and polyurethane systems

SISTEMA RECOMENDADO

CAPAS SIGUIENTES

Complete with 659 Genfloor Topcoat SF, 660 Self-Levelling or 665 Chem Coating.

El sistema adecuado para su suelo, con el equipo técnico de Genfloor.

Nuestros expertos le acompañan en cada fase del proyecto: análisis del suelo, medición de humedad, selección del sistema y cálculo de consumo.

bottom of page