top of page

Genfloor / Primers and Impregnations / 646 Genfloor Novolac Epoxy Concrete Primer

Gen Boya 646 Genfloor Novalak Epoksi Beton Astarı ambalaj görseli

PRIMERS AND IMPREGNATIONS · CHEMICAL-RESISTANT PRIMER

646

Genfloor Novolac Epoxy Concrete Primer

2K · Novolac epoxy · Chemical resistance

Clear novolac (phenolic) epoxy concrete primer with excellent chemical and solvent resistance.

An unfilled, clear, two-component primer based on novolac (phenolic) epoxy with a modified phenolic polyamine hardener. It offers excellent adhesion, mechanical strength and outstanding resistance to water, chemicals and solvents.

Technical Data

LIGANTE

Novolac (phenolic) epoxy

COMPONENTES

Two-component (2K)

POSICIÓN EN EL SISTEMA

Chemical-resistant primer

DENSIDAD

1.10 ± 0.05 kg/L

SÓLIDOS EN VOLUMEN

Solvent-free (~100%)

DILUCIÓN

Do not thin

MÉTODO DE APLICACIÓN

Roller, brush

PREPARACIÓN DE SUPERFICIE

Milling / shot-blasting, moisture < 4%

RENDIMIENTO

—

RENDIMIENTO

—

RENDIMIENTO

—

RENDIMIENTO

—

SECADO

—

ENVASE

—

COLOR

Clear

DOCUMENTOS TÉCNICOS

Uso y aplicación

USOS

Used on concrete and steel surfaces requiring excellent chemical resistance to salt and fresh water, petroleum products, crude oil, alkalis and weak acids.

 

PREPARACIÓN DE SUPERFICIE Y APLICACIÓN

New concrete must be cured for at least 28 days; surface moisture must not exceed 4%. Remove weak surface layers, laitance, oil, curing compounds and old coating residues by milling, shot-blasting or diamond grinding; remove the dust with an industrial vacuum. Repair cracks and holes with epoxy repair mortar. Mix components A and B with a low-speed mechanical mixer until homogeneous (at least 2–3 minutes) and apply the mix within its pot life. Apply by roller or brush. Ambient and floor temperature must be between +10 °C and +30 °C and relative humidity below 80%; floor temperature must be kept at least 3 °C above the dew point.

 

ÁREAS DE APLICACIÓN

→ Chemical, Petrochemical and Treatment

 

Technical data are average values at 20 °C and 65% relative humidity. Coverage varies with surface roughness, application method and film thickness. Consult the Gen Boya technical team for project-specific system design.

CARACTERÍSTICAS PRINCIPALES

— Superior chemical resistance with novolac epoxy

— Resistance to petroleum products and crude oil

— For concrete and steel surfaces

— Primer for the Nova systems

SISTEMA RECOMENDADO

CAPAS SIGUIENTES

Complete with 656 Genfloor Nova SL Basecoat and 661 Genfloor Nova SL Topcoat.

El sistema adecuado para su suelo, con el equipo técnico de Genfloor.

Nuestros expertos le acompañan en cada fase del proyecto: análisis del suelo, medición de humedad, selección del sistema y cálculo de consumo.

bottom of page