top of page

Genfloor / Special Performance Systems / 647 Genfloor Conductive Concrete Primer

Gen Boya 647 Genfloor Conductive Concrete Primer ambalaj görseli

SPECIAL PERFORMANCE SYSTEMS · CONDUCTIVE INTERMEDIATE PRIMER

647

Genfloor Conductive Concrete Primer

2K · Solvent-free epoxy · Conductive

Solvent-free, high-strength conductive epoxy primer for antistatic and ESD floor systems.

A solvent-free, high-strength, epoxy-based conductive floor primer. Together with the antistatic topcoat it forms an earthed conductive floor system.

Technical Data

LIGANTE

Epoxy resin

COMPONENTES

Two-component (2K)

POSICIÓN EN EL SISTEMA

Conductive intermediate primer

DENSIDAD

1.10 ± 0.05 kg/L

SÓLIDOS EN VOLUMEN

Solvent-free (~100%)

DILUCIÓN

Do not thin

MÉTODO DE APLICACIÓN

Roller

PREPARACIÓN DE SUPERFICIE

Milling / shot-blasting, moisture < 4%

RENDIMIENTO

—

RENDIMIENTO

—

RENDIMIENTO

—

RENDIMIENTO

—

SECADO

—

ENVASE

—

COLOR

Black

DOCUMENTOS TÉCNICOS

Uso y aplicación

USOS

Applied in aircraft hangars, automotive plants, defence manufacturing facilities, healthcare laboratories, paint shops, electrical and electronics laboratories, and areas with sensitive electronic equipment and a high explosion risk.

 

PREPARACIÓN DE SUPERFICIE Y APLICACIÓN

New concrete must be cured for at least 28 days; surface moisture must not exceed 4%. Remove weak surface layers, laitance, oil, curing compounds and old coating residues by milling, shot-blasting or diamond grinding; remove the dust with an industrial vacuum. Repair cracks and holes with epoxy repair mortar. Prime the surface with 640 Genfloor Primer and lay copper strips for earthing. Mix components A and B with a low-speed mechanical mixer until homogeneous (at least 2–3 minutes) and apply the mix within its pot life. Apply by roller. Ambient and floor temperature must be between +10 °C and +30 °C and relative humidity below 80%; floor temperature must be kept at least 3 °C above the dew point.

 

ÁREAS DE APLICACIÓN

→ Electronics and ESD Areas

→ Aircraft Hangars and Defence Industry

 

Technical data are average values at 20 °C and 65% relative humidity. Coverage varies with surface roughness, application method and film thickness. Consult the Gen Boya technical team for project-specific system design.

CARACTERÍSTICAS PRINCIPALES

— Conductive interlayer

— Carrier primer of antistatic systems

— High strength

— Solvent-free

SISTEMA RECOMENDADO

IMPRIMACIÓN

640 Genfloor Primer

CAPAS SIGUIENTES

664 Genfloor Antistatic Coating

El sistema adecuado para su suelo, con el equipo técnico de Genfloor.

Nuestros expertos le acompañan en cada fase del proyecto: análisis del suelo, medición de humedad, selección del sistema y cálculo de consumo.

bottom of page