top of page

Genfloor / Epoxy Topcoats / 655 Genfloor HB Flex Epoxy Coating

Gen Boya 655 Genfloor HB Flex Epoksi Kaplama ambalaj görseli

EPOXY TOPCOATS · FLEXIBLE TOPCOAT

655

Genfloor HB Flex Epoxy Coating

2K · Solvent-free epoxy · Flexible

Flexible, solvent-free modified epoxy topcoat for forklift and heavy vehicle traffic.

A two-component, solvent-free flexible topcoat made of modified epoxy resin and hardener. Its flexible structure provides resistance to cracking under impact and vibration.

Technical Data

LIGANTE

Modified epoxy

COMPONENTES

Two-component (2K)

POSICIÓN EN EL SISTEMA

Flexible topcoat

DENSIDAD

1.55 kg/L

SÓLIDOS EN VOLUMEN

Solvent-free (~100%)

DILUCIÓN

Do not thin

MÉTODO DE APLICACIÓN

Trowel, squeegee, spiked roller

PREPARACIÓN DE SUPERFICIE

Milling / shot-blasting, moisture < 4%

RENDIMIENTO

—

RENDIMIENTO

—

RENDIMIENTO

—

RENDIMIENTO

—

SECADO

—

ENVASE

—

COLOR

Produced on request in colours from the RAL colour chart.

DOCUMENTOS TÉCNICOS

Uso y aplicación

USOS

Applied in warehouses, factories and workshops with forklift, loader and heavy vehicle traffic, and in production and packaging areas.

 

PREPARACIÓN DE SUPERFICIE Y APLICACIÓN

New concrete must be cured for at least 28 days; surface moisture must not exceed 4%. Remove weak surface layers, laitance, oil, curing compounds and old coating residues by milling, shot-blasting or diamond grinding; remove the dust with an industrial vacuum. Repair cracks and holes with epoxy repair mortar. Prime the surface with 645 Genfloor Primer Flex. Mix components A and B with a low-speed mechanical mixer until homogeneous (at least 2–3 minutes) and apply the mix within its pot life. Apply by trowel and squeegee. Ambient and floor temperature must be between +10 °C and +30 °C and relative humidity below 80%; floor temperature must be kept at least 3 °C above the dew point.

 

ÁREAS DE APLICACIÓN

→ Factories and Production Plants

→ Warehouses and Logistics Centres

 

Technical data are average values at 20 °C and 65% relative humidity. Coverage varies with surface roughness, application method and film thickness. Consult the Gen Boya technical team for project-specific system design.

CARACTERÍSTICAS PRINCIPALES

— Flexible, impact-absorbing film

— Resistant to heavy vehicle traffic

— Solvent-free

— Resistance to cracking

SISTEMA RECOMENDADO

IMPRIMACIÓN

645 Genfloor Primer Flex or 640 Genfloor Primer

El sistema adecuado para su suelo, con el equipo técnico de Genfloor.

Nuestros expertos le acompañan en cada fase del proyecto: análisis del suelo, medición de humedad, selección del sistema y cálculo de consumo.

bottom of page