A two-component, solvent-free, self-levelling epoxy topcoat. It forms a seamless, glossy, easy-to-clean surface with high mechanical strength and chemical resistance.

Technical Data

LIGANTE

Epoxy resin

COMPONENTES

Two-component (2K)

POSICIÓN EN EL SISTEMA

Self-levelling topcoat

DENSIDAD

1.65 ± 0.1 kg/L

SÓLIDOS EN VOLUMEN

Solvent-free (~100%)

BRILLO / ASPECTO

Gloss

RENDIMIENTO TEÓRICO

1.5 kg/m² per 1 mm thickness

PROPORCIÓN DE MEZCLA

4 : 1 by weight (A : B)

DILUCIÓN

Do not thin

MÉTODO DE APLICACIÓN

Notched trowel, squeegee, spiked roller

PREPARACIÓN DE SUPERFICIE

Milling / shot-blasting, moisture < 4%

RENDIMIENTO

—

SECADO

Dust dry 3–4 h · Touch dry 10–12 h · Full cure 7 days

ENVASE

20 kg kit (16 kg A + 4 kg B)

COLOR

Produced on request in colours from the RAL colour chart.

DOCUMENTOS TÉCNICOS

Uso y aplicación

USOS

Used in production and storage areas with forklift traffic, loading ramps, supermarkets, multi-storey and underground car parks, exhibition halls and all areas requiring mechanical resistance.

 

PREPARACIÓN DE SUPERFICIE Y APLICACIÓN

New concrete must be cured for at least 28 days; surface moisture must not exceed 4%. Remove weak surface layers, laitance, oil, curing compounds and old coating residues by milling, shot-blasting or diamond grinding; remove the dust with an industrial vacuum. Repair cracks and holes with epoxy repair mortar. Prime the surface with 640 Genfloor Primer. Mix components A and B with a low-speed mechanical mixer until homogeneous (at least 2–3 minutes) and apply the mix within its pot life. Pour the mix onto the floor, spread with a notched trowel or squeegee and de-aerate with a spiked roller. Ambient and floor temperature must be between +10 °C and +30 °C and relative humidity below 80%; floor temperature must be kept at least 3 °C above the dew point.

 

ÁREAS DE APLICACIÓN

→ Factories and Production Plants

→ Warehouses and Logistics Centres

→ Pharmaceutical, Hospital and Laboratory

→ Shopping Centres, Retail, Schools and Offices

 

Technical data are average values at 20 °C and 65% relative humidity. Coverage varies with surface roughness, application method and film thickness. Consult the Gen Boya technical team for project-specific system design.

CARACTERÍSTICAS PRINCIPALES

— Seamless, smooth and glossy surface

— Resistant to forklift and heavy traffic

— Chemical resistance

— Hygienic and easy to clean

— RAL colour options

SISTEMA RECOMENDADO

IMPRIMACIÓN

640 Genfloor Primer (with 657 Self Levelling Basecoat as intermediate coat if required)

El sistema adecuado para su suelo, con el equipo técnico de Genfloor.

Nuestros expertos le acompañan en cada fase del proyecto: análisis del suelo, medición de humedad, selección del sistema y cálculo de consumo.