top of page

Genfloor / Special Performance Systems / 664 Genfloor Antistatic Coating

Gen Boya 664 Genfloor Antistatic Coating ambalaj görseli

SPECIAL PERFORMANCE SYSTEMS · ANTISTATIC TOPCOAT

664

Genfloor Antistatic Coating

2K · Solvent-free epoxy · Antistatic

Solvent-free antistatic epoxy topcoat for areas with explosion risk and sensitive electronics.

A two-component, solvent-free, epoxy-based topcoat forming the wearing layer of the antistatic epoxy floor system. It conducts static charges to earth in a controlled way.

Technical Data

LIGANTE

Epoxy resin

COMPONENTES

Two-component (2K)

POSICIÓN EN EL SISTEMA

Antistatic topcoat

DENSIDAD

1.60 ± 0.1 kg/L

SÓLIDOS EN VOLUMEN

Solvent-free (~100%)

DILUCIÓN

Do not thin

MÉTODO DE APLICACIÓN

Notched trowel, squeegee, spiked roller

PREPARACIÓN DE SUPERFICIE

Milling / shot-blasting, moisture < 4%

RENDIMIENTO

—

RENDIMIENTO

—

RENDIMIENTO

—

RENDIMIENTO

—

SECADO

—

ENVASE

—

COLOR

Produced on request in colours from the RAL colour chart.

DOCUMENTOS TÉCNICOS

Uso y aplicación

USOS

Used on industrial floors, in hospitals, operating theatres, laboratories, production and storage areas, and in areas with sensitive electrical and electronic equipment and explosion risk.

 

PREPARACIÓN DE SUPERFICIE Y APLICACIÓN

The system is applied over 640 Genfloor Primer and 647 Conductive Primer. Mix components A and B with a low-speed mechanical mixer until homogeneous (at least 2–3 minutes) and apply the mix within its pot life. Spread with a squeegee and notched trowel and de-aerate with a spiked roller. Ambient and floor temperature must be between +10 °C and +30 °C and relative humidity below 80%; floor temperature must be kept at least 3 °C above the dew point.

 

ÁREAS DE APLICACIÓN

→ Pharmaceutical, Hospital and Laboratory

→ Electronics and ESD Areas

→ Aircraft Hangars and Defence Industry

 

Technical data are average values at 20 °C and 65% relative humidity. Coverage varies with surface roughness, application method and film thickness. Consult the Gen Boya technical team for project-specific system design.

CARACTERÍSTICAS PRINCIPALES

— Controlled dissipation of static electricity

— Safety in areas with explosion risk

— Seamless, hygienic surface

— Solvent-free

SISTEMA RECOMENDADO

IMPRIMACIÓN

640 Genfloor Primer + 647 Conductive Concrete Primer

El sistema adecuado para su suelo, con el equipo técnico de Genfloor.

Nuestros expertos le acompañan en cada fase del proyecto: análisis del suelo, medición de humedad, selección del sistema y cálculo de consumo.

bottom of page